APA rotary tee terminal
2D Drawings

Specifications
| Model | ΦD | R | L1 | L2 | L3 | L4 | L5 | ΦP | ![]() |
| APA4-M5 | 4 | M5 | 4 | 22.5 | 17 | 13 | 11 | 11 | 8 |
| APA6-01 | 6 | R1/8 | 7 | 24 | 24 | 20 | 13 | 13 | 12 |
| APA8-01 | 8 | R1/8 | 7 | 26 | 24 | 20 | 14.5 | 14.5 | 12 |
| APA8-02 | R1/4 | 9.5 | 28 | 26.5 | 20.5 | 14.5 | 14.5 | 14 | |
| APA10-02 | 10 | R1/4 | 9.5 | 31 | 26.5 | 20.5 | 18.5 | 18.5 | 14 |
| APA10-03 | R3/8 | 10.5 | 33 | 32 | 25.5 | 18.5 | 18.5 | 19 | |
| APA12-03 | 12 | R3/8 | 10.5 | 34 | 32 | 25.5 | 21 | 21 | 19 |
| APA12-04 | R1/2 | 14 | 36.5 | 39 | 31 | 21 | 21 | 24 | |
| APA6-G01 | 6 | G1/8 | 5 | 24 | 23.5 | 18.5 | 13 | 13 | 12 |
| APA8-G01 | 8 | G1/8 | 5 | 26 | 23.5 | 18.5 | 14.5 | 14.5 | 12 |
| APA8-G02 | G1/4 | 7.5 | 28 | 27 | 19.5 | 14.5 | 14.5 | 14 | |
| APA10-G02 | 10 | G1/4 | 7.5 | 31 | 27 | 19.5 | 18.5 | 18.5 | 14 |
| APA10-G03 | G3/8 | 7.5 | 33 | 32 | 24.5 | 18.5 | 18.5 | 19 | |
| APA12-G03 | 12 | G3/8 | 7.5 | 34 | 32 | 24.5 | 21 | 21 | 19 |
| APA12-G04 | G1/2 | 10 | 36.5 | 39 | 29 | 21 | 21 | 24 |
description2
-
Q: What is the temperature resistance limit of the connector? Can it be used in high temperature environments?
A: The standard operating temperature is -20℃ to 80℃. If a higher temperature (such as above 100℃) is required, it is recommended to choose a metal connector or consult technical support.

Directional Control Valves
Air Cylinders
Rotary Actuators/Air Grippers
Vacuum Equipment
Air Preparation Equipment
Modular F.R.L.
Fittings and Tubing,Flow Control Equipment
Sensors/Switches