ANZSE30A(F) / ANISE30A Series High-Precision Digital Pressure Switch with Dual-Color Display
Product Overview
Advanced Dual-Color Digital Pressure Switch for Precision Control
The ANZSE30A(F) / ANISE30A Series Dual-Color Digital Pressure Switch is engineered for high-precision pressure monitoring and control in pneumatic and industrial automation systems.
Designed for air and inert gas applications, this compact yet powerful pressure switch delivers exceptional accuracy, fast response, and reliable visual indication, even in demanding industrial environments.
With a dual-color LED display, operators can instantly identify pressure status at a glance, improving operational efficiency and reducing setup and troubleshooting time.
Application Spotlight
・Pneumatic automation systems
・CNC machining pressure monitoring
・Vacuum and compressed air control
・Assembly lines and packaging equipment
・Industrial robots and motion control systems
Optional/Part Model
| If optional individual units are required, please order according to the following models. | ||
| Name | Model | Optional Accessories |
| Bracket A | AZS-38-A1 | Mounting Screws (M3x5L with 2) |
| Panel Mount Connector | AZS-27-C | Mounting Screws (M3x8L with 2) |
| Panel Mount Connector + Front Protective Cover | ZS-27-D | Mounting Screws (M3x8L with 2) |
| Wire with Plug | ANZS-38-3L | 3-pin, 1-output, 2m |
| Wire with Plug | ANZS-38-4L | 4-pin, 2-output, 2m |
Technical Parameters
| Model Number | ANZSE30A (For vacuum pressure) |
ANZSE30AF (For mixing and pressing) |
ANISE30A (For positive pressure) |
||
| Rated Pressure Range | 0.0~-101.0kPa | -100.0~100.0kPa | -0.100~1.000MPa | ||
| Set Pressure Range | 10.0~-105.0kPa | -105.0~105.0kPa | -0.105~1.050MPa | ||
| Guaranteed Pressure Resistance | 500kPa | 500kPa | 1.5MPa | ||
| Minimum Setting Unit | 0.1kPa | 0.1kPa | 0.001MPa | ||
| Suitable Fluid | Air, non-flammable gases, non-corrosive gases | ||||
| Power Supply Voltage | DC12~24V±10%, fluctuation (p-p) less than 10% (with reverse connection protection) | ||||
| Current Consumption | 40mA or less | ||||
| Switch Output | One NPN or PNP open collector output, two NPN or PNP open collector outputs (selectable) | ||||
| Maximum load power supply | 80mA | ||||
| Maximum applied voltage | 28V (NPN output) | ||||
| Residual voltage | 1V or less (load current 80mA) | ||||
| Response time | 2.5ms or less (oscillation prevention function: 20, 100, 500, 1000, 2000ms) | ||||
| Short circuit protection | With short circuit protection | ||||
| Repeatability | ±0.2% of full scale or less ±1 unit | ||||
| Hysteresis | Hysteresis mode | Variable from 0 (Note 1) | |||
| Upper and lower limit comparison mode | |||||
| Analog output | Voltage output (Note 2) | Output Voltage (Rated Pressure Range) |
1~5V±2.5%F.S. | 0.6~5V±2.5%F.S. | |
| Linear | ±1%F.S. | ||||
| Output Resistance | About 1kΩ | ||||
| Current output (Note 3) | Output Current (Rated Pressure Range) |
4~20mA±2.5%F.S. | 2.4~20mA±2.5%F.S. | ||
| Linear | ±1%F.S. | ||||
| Load Resistance | Maximum load resistance: 300Ω at 12V supply voltage, 600Ω at 24V supply voltage Minimum load resistance: 50Ω |
||||
| Display | 4-digit, 7-segment display, dual-color LCD (red/green) display | ||||
| Display Precision | ±2% full scale, ±1 unit (at ambient temperature 25±3℃) | ||||
| Action Indicator | When switch ON, the indicator lights up: OUT1: Green, OUT2: Red | ||||
| Environmental resistance | Protection rating | IP40 | |||
| Operating temperature range | Operating temperature: 0℃~50℃, Storage temperature: -10℃~60℃ (non-condensing and non-icing) | ||||
| Operating humidity range | Operating temperature/Storage temperature: 35~85%Rh (non-condensing) | ||||
| Withstand voltage | AC¹000V charging between the part and the housing in 1 minute | ||||
| Insulation resistance | 50MQ or higher (DC500V megohmmeter) charging between the part and the housing | ||||
| Temperature characteristics | ±2% F.S. (25℃ reference) | ||||
| Lead wires | 3-core φ3.52m 4-core conductor cross-sectional area: 0.15mm² (AWG26), insulator outer diameter: 1.0mm |
||||
| Specifications | Compliant with CE and RoHS standards | ||||
| Note 1) When the applied pressure varies around the set value, oscillation will occur if the hysteresis is not set above the variation range. Note 2) When analog voltage output is selected, analog current output cannot be selected simultaneously. Note 3) When analog current output is selected, analog voltage output cannot be selected simultaneously. |
|||||


-
Q: What makes the dual-color display useful in daily operation?
-
Q: What support do you provide before and after purchase?
A: ATG offers pre-sales selection guidance, wiring assistance, and technical support to ensure smooth integration and reliable operation throughout the product lifecycle.

Directional Control Valves
Air Cylinders
Rotary Actuators/Air Grippers
Vacuum Equipment
Air Preparation Equipment
Modular F.R.L.
Fittings and Tubing,Flow Control Equipment
Sensors/Switches