ANITVX2000 High Pressure Proportional Control Valve
Product Overview
1. Precision Engineered for Advanced Automation
The ANITVX2000 High-Precision Proportional Air Pressure Regulating Valve sets a new standard for intelligent pressure management in industrial automation. By converting a standard electrical input signal into a precisely proportional output pressure, it enables seamless, continuous control that is both responsive and remarkably stable.
2. Unmatched Performance Under Pressure
Engineered for the most challenging environments, the ANITVX2000 supports a maximum supply pressure of 5.0MPa and offers an adjustable control range from 0.01 to 3.0MPa. This wide range, combined with an exceptional flow capacity of 3000 L/min, makes it the perfect solution for heavy-duty applications requiring both high pressure and high flow. Its ±1% repeatability guarantees consistent, reliable performance cycle after cycle, minimizing process variation and ensuring product quality.
3. Designed for Versatility and Longevity
Compatible with a variety of industrial gases including Air, Nitrogen, Oxygen, and Argon, this valve is built to adapt. Key components in contact with the media are treated with high-performance fluorine-based grease, offering superior resistance to wear and oxidation for extended service life and reduced maintenance.
Application Spotlight
・Automated Pneumatic Test Stands
・Semiconductor Manufacturing Equipment
・Welding and Cutting Gas Control Systems
・Industrial Laser and CNC Machinery
・High-Precision Packaging and Material Handling
・Process Automation in Chemical and General IndustryTechnical Parameters
| Model Number | ANITVX2030 | ANITVX2030-X80 | |
| Minimum Supply Pressure | 0.5 MPa or higher than the set pressure + 0.2 MPa | ||
| Maximum Supply Pressure | 5 MPa (Note 2) | ||
| Set Pressure Range (Note 3) | 0.01~3.0MPa | ||
| Power supply | Voltage | DC24V±10% | |
| Current Consumption | Below 0.12A | ||
| Input signal | Current Type (Note 4) | DC4~20mA,DCO~20mA(Convergence) | |
| Voltage Type | DC0~5V.DC0~10V | ||
| Input impedance | Current Type | 500Ω以下 | |
| Voltage Type | 6~6.5KΩ (at room temperature) | ||
| Output signal (Note 5) (Monitoring output) | Analog output | DC 1~5V (output impedance approx. 1KΩ) Output accuracy ±6% or less (range) |
|
| 4~20mA (mass type) Load impedance 250Ω or less Output accuracy ±6% or less (range) |
|||
| Switch output | NPN open collector output maximum 30V, 80mA | ||
| Hysteresis ±3% (range), self-diagnostic ±5% or less (range) | |||
| PNP open collector output maximum 80mA | |||
| Hysteresis ±3% (range), self-diagnostic ±5% or less (range) | |||
| Linearity | ±1% or less (range) | ||
| Hysteresis Accuracy | 1% or less (range) | ||
| Repeatability | ±1% or less (range) | Set pressure: 0~0.9 MPa | |
| Set pressure: 0.9~3 MPa | |||
| Pressure Stability | 1% or less (range) | Set pressure: 0~0.9 MPa | |
| Set pressure: 0.9~3 MPa | |||
| Sensitivity | ±1% or less (range) | ||
| Temperature Characteristics | ±0.12% or less (range)/℃ | ||
| Output pressure display | Precision | ±2% or less (range) ±1dig | |
| Smallest unit (Note 6) | MPa:0.01,kgf/cm²:0.1,bar:0.1,ps:1 | ||
| Fluid used | Air, N2, O2, Ar | ||
| Ambient temperature and fluid temperature | 0-50℃ (non-condensing) | ||
| Mass | Approx. 570g (excluding options) | ||
| Note 1) The above characteristic values were measured using the piping system shown in Figure 1. Note 2) When using oxygen as the fluid, please use it with a maximum supply pressure below 1 MPa. Note 3) When using oxygen as the fluid, please use it with a maximum supply pressure below 1 MPa. Note 4) Not applicable to 2-wire DC 4~20mA. Requires a DC 24V power supply. Note 5) Choose either analog output or switch output. After selecting switch output, choose either NPN output or PNP output. When measuring DC 1-5V analog output with a load impedance below 100kΩ, the analog output accuracy may be less than ±6%. Note 6) Zero point and range are adjusted using the smallest unit of the output pressure display. Units cannot be switched. Note 7) This product is suitable for blowing. When used in applications other than blowing (driving, sealing), pressure control is not ideal. |
|||
Order Code
ANITVX2030 series high-pressure proportional valve order code
Indication symbols

Overall Dimension

FAQ
-
Q: Is it suitable for harsh environments?
A: The valve is designed for industrial environments. For specific conditions (extreme temperatures, washdown, hazardous areas), consult the datasheet for ingress protection (IP) ratings and material certifications.
-
Q: Is it suitable for oxygen service?
A: Yes, it is compatible with oxygen (O₂). However, ensure the system is clean and assembled according to oxygen service standards to prevent fire hazards. Consult our technical team for specific guidelines.