AMXQ Series High Interchangeability Sliding Cylinder
Description
The AMXQ Series Pneumatic Slide Table – High Interchangeability Type is designed for industrial applications that demand precise linear motion and flexibility. This slide table features a high interchangeability design, ensuring compatibility and ease of integration with various systems. Its robust construction and precision engineering provide enhanced stability and performance, making it ideal for a wide range of automation and assembly processes.
Symbol

Specification
| Cylinder Diameter (mm) | 6 | 8 | 12 | 16 | 20 | 25 |
| Pipe Connection Diameter | M5×0.8 | |||||
| Fluid | Air | |||||
| Actuation | Double-acting type | |||||
| Operating Pressure | 0.15~0.7MPa Note 1) (End lock: 0.35~0.7MPa) | |||||
| Guaranteed Proof Pressure | 1.05MPa | |||||
| Ambient Temperature and Fluid Temperature | -10~60℃ | |||||
| Operating Speed Range (Average Actuating Speed) |
50-500mm/s (with metal stopper: 50-300mm/s) (metal stopper: 50-200mm/s) P83 standard stroke table (*) indicates 50-300mm/s |
|||||
| Cushioning (Without Stroke Adjuster) |
Internal rubber buffer | |||||
| Cushioning (With Stroke Adjuster) |
Metal stopper with buffer, rubber stopper, hydraulic buffer, metal stopper | |||||
| Lubrication | No oil supply | |||||
| Auto Switch | Solid-state auto switches, Reed-state auto switches (2-wire, 3-wire), 2-color display solid-state auto switches (2-wire, 3-wire) | |||||
| Stroke Length Tolerance | +2~0mm | |||||
| [Note] Minimum operating pressure for metal stoppers with buffers: The pressure required to completely retract the protruding portion of the buffer until it contacts the metal portion of the stopper. For hydraulic buffers with a cylinder diameter of φ20, the operating pressure is 0.15 to 0.6 MPa. |
||||||
Regulator installation position (Except centralized regulator)
Shortened length
Centralized adjuster installation position
Standard Type
φ6~φ12
φ16~φ25
Symmetry Type
φ6~φ12
φ16~φ25
Ordering Code

Expanded Specifications
With end lock specifications
| Model | AMXQ6 | AMXQ8 | AMXQ12 | AMXQ16 | AMXQ20 | AMXQ25 |
| Operating Pressure Range (MPa) | 0.35~0.7 | |||||
| Holding Force (N) | 12 | 12 | 23 | 45 | 70 | 110 |
Specifications with buffer mechanism
| Model | AMXQ6 | AMXQ8 | AMXQ12 | AMXQ16 | AMXQ20 | AMXQ25 | |
| Operating speed range (mm/s) | 50~500 (50~300 when used horizontally) | ||||||
| Cushion stroke (mm) | 5 | 10 | |||||
| Buffer stroke load (N) | When the stroke is 0mm | 3 | 5 | 9 | 16 | 25 | 40 |
| When the stroke is maximum | 6 | 8 | 15 | 24 | 38 | 59 | |
Magnetic switch for buffer part
| Type | Model | Specifications | Wire lead-out direction |
| Non-contact magnetic switch | D-M9BV | With indicator light, 2-wire | Longitudinal |
| D-M9NV | With indicator light, 3-wire, output type: NPN | ||
| D-M9PV | With indicator light, 3-wire, output type: PNP |
Regulator specifications
Specifications of metal stopper with buffer
| Model | AMXQ8 | AMXQ12 | AMXQ16 | AMXQ20 | AMXQ25 |
| Maximum Absorbed Energy (J) | 0.018 | 0.04 | 0.08 | 0.12 | 0.18 |
| Absorbing Stroke (mm) | 2 | 2.8 | 3.6 | 4.4 | 5.5 |
| Minimum Operating Pressure with Metal Stopper (MPa) | 0.3 | 0.3 | 0.2 | 0.2 | 0.2 |
| Buffer Pressure Recoil (N) | 20 | 42 | 65 | 97 | 154 |
| Mounting Screw Size (mm) | M6×0.75 | M8×1 | M10×1 | M12×1 | M14×1.5 |
| * Minimum pressure required to push the extended portion of the buffer back into contact with metal. For positioning applications, the pressure must be greater than the minimum operating pressure of the metal stopper with buffer. For vertical mounting, the workpiece mass must be considered. * φ6 is not specified. |
|||||
Rubber buffer specifications
| Model | AMXQ6 | AMXQ8 | AMXQ12 | AMXQ16 | AMXQ20 | AMXQ25 |
| Maximum Absorbed Energy (J) | 0.06 | 0.12 | 0.2 | 0.4 | 0.6 | |
| Mounting Screw Size (mm) | M6×0.75 | M8×1 | M10×1 | M12×1 | M14×1.5 | |
Buffer/RJ specifications
| Model | AMXQ6 | AMXQ8 | AMXQ12 | AMXQ16 | AMXQ20 | AMXQ25 |
| Maximum Absorbed Energy (J) | 0.35 | 0.5 | 1.5 | 3 | 3.7 | |
| Absorbing Stroke (mm) | 3 | 5 | 6 | 7 | 10 | |
| Impact Speed (mm/s) | 50~500 | |||||
| Maximum Operating Frequency (cycle/min) | 80 | 80 | 70 | 45 | ||
| Maximum Allowable Thrust (N) | 150 | 245 | 422 | 814 | ||
| Spring Force (Extension) (N) | 1.3 | 2.8 | 5.4 | 6.4 | ||
| Spring Force (Compression) (N) | 3.9 | 4.9 | 8 | 15 | ||
| Mounting Screw Size (mm) | M6×0.75 | M8×1 | M10×1 | M14×1.5 | ||
Metal stopper specifications
| Model | AMXQ6 | AMXQ8 | AMXQ12 | AMXQ16 | AMXQ20 | AMXQ25 |
| Maximum Absorbed Energy (J) | 0.009 | 0.02 | 0.04 | 0.06 | 0.09 | |
| Mounting Screw Size (mm) | M6×0.75 | M8×1 | M10×1 | M12×1 | M14×1.5 | |
External specifications


| Model | F | G | GA | GB | H | HA | HB | I | J | M | N | NN | Z | ZZ |
| AMXQ6-10Z | 22 | 18 | 25 | 9 | 23 | 16 | 38 | 10 | 30 | 64.5 | 4 | 2 | 50 | 60 |
| AMXQ6-20Z | 25 | 15 | 15 | 9 | 26 | 26 | 38 | 10 | 30 | 74.5 | 4 | 2 | 50 | 60 |
| AMXQ6-30Z | 21 | - | 34 | 12 | - | 20 | 48 | 13 | 40 | 95.5 | 6 | 3 | 63 | 73 |
| AMXQ6-40Z | 26 | 10 | 38 | 24 | 28 | 28 | 48 | 15 | 50 | 107.5 | 6 | 3 | 75 | 85 |
| AMXQ6-50Z | 27 | 20 | 48 | 34 | 28 | 28 | 48 | 15 | 60 | 117.5 | 6 | 3 | 85 | 95 |
| [Note 1] If the workpiece securing screw is too long, it may hit the guide block and cause malfunction. Use screws with a length between the maximum and minimum screw insertion depths. [Note 2] Because the slide is magnetic, attached magnets, etc., may become magnetized and cause malfunction of the auto switch. |
||||||||||||||



| Model | F | G | GA | GB | H | HA | HB | I | J | M | N | NN | Z | ZZ |
| AMXQ8-10Z | 25 | 15 | 21 | 9 | 25 | 19 | 37 | 10 | 26.5 | 68.5 | 4 | 2 | 51 | 61 |
| AMXQ8-20Z | 25 | 22 | 22 | 16 | 28 | 28 | 40 | 14 | 32.5 | 78.5 | 4 | 2 | 61 | 71 |
| AMXQ8-30Z | 26 | - | 33 | 26 | - | 27 | 40 | 14.5 | 42 | 88.5 | 6 | 3 | 71 | 81 |
| AMXQ8-40Z | 32 | 14 | 45 | 27 | 31 | 31 | 55 | 20 | 52.5 | 104.5 | 6 | 3 | 87 | 97 |
| AMXQ8-50Z | 46 | 16 | 45 | 54 | 29 | 58 | 55 | 37 | 62.5 | 131.5 | 6 | 4 | 114 | 124 |
| AMXQ8-75Z | 50 | 15 | 45 | 56 | 30 | 60 | 55 | 10 | 91.5 | 156.5 | 6 | 4 | 116 | 126 |
| [Note 1] If the workpiece securing screws are too long, they may hit the guide block and cause malfunction. Use screws whose length falls between the maximum and minimum screw insertion depths. [Note 2] Since the slide is magnetic, proximity to a magnet can cause it to become magnetized, potentially causing malfunction of the auto switch. |
||||||||||||||


| Model | F | G | GA | GB | H | HA | HB | I | J | M | N | NN | Z | ZZ |
| AMXQ12-10Z | 28 | 17 | 17 | 11 | 32 | 32 | 46 | 11 | 32 | 82.5 | 4 | 2 | 62.5 | 75 |
| AMXQ12-20Z | 28 | 19 | 19 | 11 | 32 | 32 | 48 | 13 | 32 | 92.5 | 4 | 2 | 64.5 | 77 |
| AMXQ12-30Z | 38 | 21 | 21 | 11 | 40 | 40 | 58 | 15 | 40 | 102.5 | 4 | 2 | 74.5 | 87 |
| AMXQ12-40Z | 34 | - | 40 | 27 | - | 39 | 60 | 23 | 50 | 120.5 | 6 | 3 | 92.5 | 105 |
| AMXQ12-50Z | 34 | 11 | 50 | 37 | 39 | 39 | 60 | 23 | 60 | 130.5 | 6 | 3 | 102.5 | 115 |
| AMXQ12-75Z | 36 | 25 | 61 | 41 | 36 | 72 | 100 | 42 | 85 | 174.5 | 8 | 4 | 146.5 | 159 |
| AMXQ12-100Z | 36 | 14 | 86 | 66 | 36 | 72 | 100 | 42 | 110 | 199.5 | 10 | 5 | 171.5 | 184 |
| [Note 1] If the workpiece securing screw is too long, it may hit the guide block and cause malfunction. Use screws with a length between the maximum and minimum screw insertion depths. [Note 2] Since the slide is a magnetic material, it may become magnetized if it comes into contact with a magnet, etc., causing the auto switch to malfunction. |
||||||||||||||

| Model | F | G | GA | GB | H | HA | HB | l | J | M | N | NN | Z | ZZ |
| AMXQ16-10Z | 38 | 16 | 16 | 8 | 39 | 39 | 58 | 22 | 28 | 98.5 | 4 | 2 | 72.5 | 87 |
| AMXQ16-20Z | 38 | 20 | 20 | 12 | 39 | 39 | 58 | 15 | 39 | 108.5 | 4 | 2 | 76.5 | 91 |
| AMXQ16-30Z | 48 | 21 | 21 | 30 | 48 | 48 | 50 | 16 | 48 | 118.5 | 4 | 2 | 86.5 | 101 |
| AMXQ16-40Z | 58 | 28 | 28 | 17 | 58 | 58 | 80 | 23 | 58 | 135.5 | 4 | 2 | 103.5 | 118 |
| AMXQ16-50Z | 40 | - | 51 | 27 | - | 45 | 80 | 28 | 63 | 145.5 | 6 | 3 | 113.5 | 128 |
| AMXQ16-75Z | 56 | 23 | 75 | 58 | 52 | 52 | 80 | 34 | 88 | 176.5 | 6 | 3 | 144.5 | 159 |
| AMXQ16-100Z | 44 | 39 | 83 | 102 | 44 | 88 | 80 | 53 | 113 | 220.5 | 8 | 4 | 188.5 | 203 |
| AMXQ16-125Z | 44 | 20 | 108 | 127 | 44 | 88 | 80 | 53 | 138 | 245.5 | 10 | 5 | 213.5 | 228 |
| [Note 1] If the workpiece securing screws are too long, they may hit the guide block and cause malfunction. Use screws whose length falls between the maximum and minimum screw insertion depths. [Note 2] Since the slide is magnetic, proximity to a magnet can cause it to become magnetized, potentially causing malfunction of the auto switch. |
||||||||||||||


| Model | F | G | GA | GB | H | HA | HB | I | J | M | N | NN | Z | ZZ |
| AMXQ20-10Z | 45 | 18 | 14 | 8 | 46 | 50 | 70 | 24.5 | 34 | 113.5 | 4 | 2 | 85 | 104 |
| AMXQ20-20Z | 40 | 18 | 14 | 8 | 46 | 50 | 70 | 24.5 | 34 | 123.5 | 4 | 2 | 85 | 104 |
| AMXQ20-30Z | 48 | 28 | 24 | 18 | 46 | 50 | 70 | 22.5 | 46 | 133.5 | 4 | 2 | 95 | 114 |
| AMXQ20-40Z | 58 | 28 | 28 | 18 | 56 | 56 | 80 | 22.5 | 56 | 143.5 | 4 | 2 | 105 | 124 |
| AMXQ20-50Z | 42 | 一 | 52 | 34 | 一 | 48 | 80 | 30.5 | 64 | 159.5 | 6 | 3 | 121 | 140 |
| AMXQ20-75Z | 55 | 22 | 78 | 58 | 56 | 56 | 90 | 38.5 | 90 | 193.5 | 6 | 3 | 155 | 174 |
| AMXQ20-100Z | 50 | 16 | 72 | 108 | 56 | 112 | 90 | 63.5 | 115 | 266.5 | 8 | 4 | 205 | 224 |
| AMXQ20-125Z | 55 | 32 | 91 | 133 | 59 | 118 | 90 | 63.5 | 140 | 291.5 | 8 | 4 | 230 | 249 |
| AMXQ20-150Z | 62 | 48 | 110 | 158 | 62 | 124 | 90 | 63.5 | 165 | 316.5 | 8 | 4 | 255 | 274 |
| [Note 1] If the workpiece securing screws are too long, they may hit the guide block and cause malfunction. Use screws whose length falls between the maximum and minimum screw insertion depths. [Note 2] Since the slide is magnetic, proximity to a magnet can cause it to become magnetized, potentially causing malfunction of the auto switch. |
||||||||||||||


| Model | F | G | GA | GB | H | HA | HB | I | J | M | N | NN | Z | ZZ |
| AMXQ25-10Z | 55 | 18 | 18 | 7 | 55 | 55 | 80 | 30 | 36 | 131.5 | 4 | 2 | 95 | 118 |
| AMXQ25-20Z | 46 | 18 | 18 | 7 | 55 | 55 | 80 | 30 | 36 | 141.5 | 4 | 2 | 95 | 118 |
| AMXQ25-30Z | 55 | 28 | 28 | 17 | 55 | 55 | 80 | 22 | 54 | 151.5 | 4 | 2 | 105 | 128 |
| AMXQ25-40Z | 65 | 28 | 28 | 17 | 65 | 65 | 90 | 22 | 64 | 161.5 | 4 | 2 | 115 | 138 |
| AMXQ25-50Z | 75 | 36 | 36 | 20 | 80 | 80 | 110 | 43 | 66 | 184.5 | 4 | 2 | 138 | 161 |
| AMXQ25-75Z | 60 | - | 76 | 45 | 一 | 65 | 110 | 42 | 92 | 209.5 | 6 | 3 | 163 | 186 |
| AMXQ25-100Z | 48 | 20 | 64 | 46 | 44 | 88 | 120 | 28 | 117 | 250.5 | 8 | 4 | 174 | 197 |
| AMXQ25-125Z | 60 | 18 | 84 | 60 | 66 | 132 | 170 | 67 | 142 | 314.5 | 8 | 4 | 238 | 261 |
| AMXQ25-150Z | 65 | 43 | 109 | 85 | 66 | 132 | 170 | 66 | 168 | 339.5 | 8 | 4 | 263 | 286 |
| [Note 1] If the workpiece securing screws are too long, they may hit the guide block and cause malfunction. Use screws whose length falls between the maximum and minimum screw insertion depths. [Note 2] Since the slide is magnetic, proximity to a magnet can cause it to become magnetized, potentially causing malfunction of the auto switch. |
||||||||||||||
FAQ
-
Q1: Does this cylinder require additional lubrication?
A: No. The AMXQ series sliding cylinder is designed to require no lubrication and is easy to maintain.
-
Q2: What does "high interchangeability" design mean?
A: High interchangeability means the AMXQ series slide cylinders can be easily integrated with a variety of systems, offering strong compatibility and facilitating quick installation and replacement in automated equipment.

Directional Control Valves
Air Cylinders
Rotary Actuators/Air Grippers