The AMHY2 Series 180° Open/Close Cam Type Air Gripper is a high-precision pneumatic gripper designed for applications requiring wide opening angles and reliable gripping. With its 180° opening angle, this gripper is ideal for handling a variety of workpieces in automation systems. The cam type mechanism ensures smooth and consistent operation, making it suitable for diverse industrial applications.
Symbol

Specification
| Operating fluid | Air |
| Operating pressure | 0.1-0.6 MPa |
| Ambient temperature and operating fluid temperature | -10-60°C |
| Repeatability | ±0.2 mm |
| Maximum operating frequency | 60 c.p.m. |
| Lubrication | No lubrication |
| Actuation method | Double-acting |
| Magnetic switch (optional) | Solid contact magnetic switch (3-wire, 2-wire) |
Model Specification
| Model | Cylinder diameter (mm) | [Note 1] Clamping torque N.m (effective value) | Opening and closing angle (both sides) | [Note 2] Mass g | |
| Open side | Closed side | ||||
| AMHY2-10D | 10 | 0.16 | 180° | -3° | 70 |
| AMHY2-16D | 16 | 0.54 | 150 | ||
| AMHY2-20D | 20 | 1.1 | 320 | ||
| AMHY2-25D | 25 | 2.28 | 560 | ||
| [Note 1] Value at a pressure of 0.5 MPa. [Note 2] Mass excluding the auto switch. |
|||||
Internal structure and main parts materials
Finger closed state
Finger open state

| Serial number | Part Name | Material | Note |
| 1 | Body | Aluminum alloy | Hard anodizing |
| 2 | Piston | φ10: Stainless steel φ16-25: Aluminum alloy |
φ16-25: Hard anodizing |
| 3 | Connector | Stainless steel | Heat treatment |
| 4 | Gripper Finger | Stainless steel | Heat treatment |
| 5 | End Cap | Resin | |
| 6 | Wear Ring | Resin | |
| 7 | Shaft | Stainless steel | Nitriding |
| 8 | Guide Bushing A | Sintered alloy steel | |
| 9 | Guide Bushing B | Sintered alloy steel | |
| 10 | End Plate | Stainless steel | |
| 11 | Cushion Pad | Polyurethane rubber | |
| 12 | Needle Roller | High carbon chromium bearing steel | |
| 13 | Fitting Wheel | Carbon steel | Nitriding |
| 14 | Rubber Magnetic Ring | Synthetic rubber | |
| 15 | C-Type Elastic Retaining Ring | Carbon steel | Phosphate coating |
| 16 | Piston Screw | Stainless steel |
External specifications


[Note] To avoid interference between accessories and the main body, do not allow accessories to extend beyond their installation restriction area during design.

[Note] To avoid interference between accessories and the main body, do not allow accessories to extend beyond their installation restriction area during design.

[Note] To avoid interference between accessories and the main body, do not allow accessories to extend beyond their installation restriction area during design.

[Note] To avoid interference between accessories and the main body, do not allow accessories to extend beyond their installation restriction area during design.
Ordering Code
description2
FAQ
-
Q: This air gripper has a repeatability of ±0.02mm. How can this accuracy be maintained in practice?
A: This requires careful consideration of both the installation and the operating environment: ① Ensure the gripper's mounting surface is flat during installation to avoid movement deviation due to tilted mounting. It is recommended to use a spirit level to calibrate the mounting base. ② Manage ambient temperature fluctuations and avoid prolonged exposure to extreme temperatures below -10°C or above 60°C. Sudden temperature fluctuations can affect the accuracy of internal components. ③ Avoid subjecting the gripper to lateral forces. When gripping a workpiece, ensure that the force applied aligns with the gripper's movement. Lateral forces can increase component wear and reduce positioning accuracy.