Leave Your Message

A4V Series Solenoid Valve

・Sliding column structure, good sealing, sensitive response

・Equipped with manual device, easy to install and debug

・Energy-saving and durable, long life

・Multiple standard voltages available

・Compatible with multiple fluids

・Can be integrated with the base valve group to save installation space

    Technical Parameters

    2D Drawings

    SCDC (5)

    Specifications

    A4V Five-way valve specifications
    Series A4V100-M5/06 A4V200-06/08 A4V300-08/10 A4V400-10/15
    Operating pressure range (MPa) 0.15-0.8
    Use medium through 40um Compressed air filtered by filter element
    Ambient temperature and medium temperature () -10~60(But not frozen)
    Pipe diameter M5:Air
    Intake=Vent=exhaust=M5
    06:Air
    Intake=Vent=exhaust=1/8
    08:Air
    Intake=Vent=exhaust=1/4
    10:Air
    Intake=Vent=exhaust=3/8
    06:Air
    Intake=Vent=exhaust=1/8
    08:Air
    Intake=Vent=1/4,exhaust=1/8
    10:Air
    Intake=Vent=3/8,exhaust=1/4
    15:Air
    Intake=Vent=exhaust=1/2
    Control method Internal pilot
    Guaranteed pressure resistance (MPa) 1.2 
    Maximum operating frequency (Hz) Two-position five-way
    Three positions and five connections
    Effective cross-sectional area (mm²) Two-position five-way M5:5.5/06:12 06:14/08:16 08:25/10:30 10:42/15:50
    Three positions and five connections M5:5/06:9 12  18  42 
    Outlet mode Terminal type/Lead Type
    Rated coil voltageV DC 12/24
    AC 24/110/220
    Allowable voltage fluctuation DCVoltage±10 % ACVoltage±15%
    Power consumption (W/VA) Coil/Voltage DC12 DC24 AC24 AC110 AC220
    100Coil 2.8  2.8  3.0/5.0
    200Coil 4.8  4.8  3.5/5.5
    Protection level IP65

                 A3V Three-way valve specifications
    Series A3V100-M5/06 A3V200-06/08 A3V300-08/10 A3V400-10/15
    Operating pressure rangeMPa 0.15-0.8
    Use medium through 40um Compressed air filtered by filter element
    Ambient temperature and medium temperature  -10~60(But not frozen)
    Pipe diameter M5:Air Intake=Vent=exhaust=M5 06:Air Intake=Vent=exhaust=1/8 08:Air Intake=Vent=exhaust=1/4 10:Air Intake=Vent=exhaust=3/8
    06:Air Intake=Vent=exhaust=1/8 08:Air Intake=Vent=exhaust=1/4 10:Air Intake=Vent=exhaust=3/8 15:Air Intake=Vent=exhaust=1/2
    Control method Internal pilot
    Guaranteed pressure resistanceMPa 1.2 
    Maximum operating frequencyHz
    Effective cross-sectional areamm² M5:5/06:12 06:14/08:16 08:25/10:30 10:42/15:50
    Outlet mode Terminal type/Lead Type
    Rated coil voltageV DC 12/24
    AC 24/110/220
    Allowable voltage fluctuation DCVoltage±10% ACVoltage±15%
    Power consumption W/VA Coil/Voltage AC12 DC24 AC24 AC110 AC220
    100Coil 2.8  2.8  3.0/5.0
    200Coil 4.8  4.8  3.5/5.5
    Protection level IP65

    Order Example

    PDF

    FAQ

    description2

    Product Information

    A4V Series Solenoid Valve PDF

    FAQ

    • Q: Will the high temperature of the medium affect the use?

      A: The standard sealing material has a temperature resistance of about -5℃~80℃. Heat-resistant seals (such as fluororubber) are required for high-temperature working conditions.